Why does Hach offer such a wide portfolio of turbidimeters?

Document ID

Document ID CO21

Published Date

Published Date 30/04/2018
Question
Why does Hach offer such a wide portfolio of turbidimeters?
Summary
Short explanation of available online and laboratory turbidimeters based on application
Answer
Hach provides a wide array of products so that customers can choose the best option to have the best possible measurement for their application.
 
Application Online Measurement Laboratory Measurement
Drinking Water
-Clarifier effluent
-Filter effluent
-Distribution System
-Elevated Tank
 
Power
-In-plant water testing
 
Food and Beverage
-Discharge to environment
TU5300 sc and TU5400 sc
The strength of the TU5 Series turbidimeters is in their 360°x90° Detection Technology™ that brings superior performance in measuring low turbidity levels, their ability to provide a fast and accurate response to potential issues in treatment process, automatic cleaning to further minimize maintenance efforts, and seamless verification between laboratory and online measurements.
TU5200
The TU5 Series benchtop turbidimeters for drinking water and other clean water applications feature a revolutionary 360° x 90° Detection Technology™ that is engineered to see more of your sample than any other turbidimeter. They also offer seamless verification between laboratory and online instruments.
Drinking Water
-Raw Water
-Clarifier effluent
-Filter backwash
 
Wastewater/Food & Beverage
-Raw sewage
-Aeration basin
-Reverse activated sludge
-Thickening/digestion
-Secondary clarification
-Discharge to environments
 
Power
-Raw water when using river water source
 
Solitax sc
Solitax sc and TSS sc turbidimeters are ideal for in-pipe or immersion applications and have automatic cleaning to prevent sensor fouling. These sensors also provide capability to measure suspended solids.
TL23 Series
The TL23 Series benchtop turbidimeters for a wide range of turbidity applications feature the trusted technology of Hach’s legacy benchtop turbidimeters and improved functionality to simplify testing. Built-in ratio technology allows for accurate measurement of high turbidity applications with mitigation of interferences from color and larger particles.
Drinking Water
-Raw Water
-Clarifier effluent
 
Wastewater
-Discharge to environment
 
Power
-Raw water when using river water source
 
Surface Scatter 7 sc
High solids can foul traditional turbidimeters. The patented optical design of the Surface Scatter 7 sc is ideal for applications where high solids would have an impact on turbidity measurement.
High Salinity Applications
-Desalination plants
-Seawater measurement
Ultraturb Seawater sc
Ultraturb Seawater sc offers accurate and reliable measurement for samples with high salinity. It also uses ratio methodology with detection at 90° and 180° to minimize the effect of sample fouling.